Kathon FP1.5 Data Sheet

Product Data Sheet for KATHON(TM) FP1.5 Fuel Biocide

DESCRIPTION
KATHONĀ® FP 1.5 microbiocide from Rohm and Haas is a patented, high performance antimicrobial agent, developed specially to combat problems of microbial contamination and spoilage in hydrocarbon fuels. KATHON FP 1.5 is a broad spectrum preservative and disinfectant for the treatment of diesel fuels, kerosenes, heating oils and aviation fuels, the active components being isothiazolone compounds.
 
As water finds its way into fuel storage tanks, often observed as fuel haziness, microorganisms breed, forming slime and emulsion that leads to filter blockage and corrosion of metal tanks. Once transported, the contaminated fuel contains the accumulated bacteria and fungi which cause the blockage of downstream filters, pumps and injectors.
 
Treatment with KATHON FP 1.5 will kill off bacterial and fungal contamination and assist the breakdown of slimes and coagulated biological sludges. This will help to prevent filters from blinding, and allow clean fuel to flow normally. An extra advantage is the elimination of the often deep emulsion layer at the fuel/water interface which will facilitate water removal by draining or by the fuel line separator. It is this emulsion that is often the critical problem when it enters the fuel line after fuel contents of a tank are disturbed or shaken.
 
Fuel treated with KATHON FP 1.5 will remain protected from contamination over extended periods of time. It will also resist contamination if re-inoculated from other sources. In studies conducted over an 8 week period, contaminated fuels were treated with fuel biocides. The fuel treated with KATHON FP 1.5 remained free from contamination for the duration of the trial. None of the competitive products evaluated could match this performance.
 
KATHON FP 1.5 has outstanding performance in a variety of applications and has wide ranging approvals and endorsements for use in aviation, marine, automotive, home heating and military fuels. Full details of approvals for KATHON FP 1.5 are contained in a separate bulletin.

AVIATION APPLICATION
A dose rate of 100ppm with a minimum retention time of 12 hours should be used in JET A1 fuel and all other aviation applications.

OTHER APPLICATION
KATHON FP 1.5 is normally dosed at the rate of approximately 300 ppm, which corresponds to 0.3 kg per 1000 litres of fuel volume. If Kathon FP1.5 is being dosed as a precautionary measure, when there is no evidence of microbial contamination, a lower dosage rate of approximately 150 ppm (0.15 kg per 1000 litres) will be appropriate. In cases of severe contamination, however, a dosage rate of up to 1000 ppm (1 kg per 1000 litres) should be used. The higher dosage rates in these circumstances will also help to improve filter fuel flow in the short term. At 300 ppm a minimum retention time of 12 hours should be maintained but this may be reduced at the higher dosage rates. In general, the higher the concentration of biocide, the shorter the contact time required for a more complete kill but in all cases 24 hours retention is sufficient.
 
Where possible, water and sludge should be removed from fuel tanks before dosing Kathon FP1.5 and also after the retention period. If this is not feasible, filters should be checked more frequently for a short period, due to microbial slimes being killed off and dislodged.
 
Ideally, KATHON FP 1.5 should be dosed shortly before the tank is re-filled with fresh fuel. The resulting agitation of the fuel then ensures uniform mixing of the biocide throughout the tank. Kathon FP1.5 can be added directly to the tank in such cases. If dosing cannot be carried out shortly before a fuel delivery, it is preferable to dissolve the KATHON FP 1.5 in a small quantity of fuel, then add the solution to the tank. Tanks must be at least 10% full before dosing and preferably fill the tank after dosing.
 
Depending upon site circumstances, it may sometimes be necessary to neutralise residual biocide before discharging treated water bottoms to the foul drain.
 
 
Links to further information

For other Kathon data, including MSDS, the current brochure and the approval and compatibiltiy list, please refer to our Documentation section.

How to Order

Call or email us to place your order. We accept ALL major credit and debit cards, bank transfer and also PayPal. 

Contact Us TabPhone copy



 

Expert advice

Unsure which spare parts you require? Or if a Separ filter will meet your requirements? 

Talk to our expert team. Call 01923 276 007

swk200010trans

 

Delivery options

We have a wide range of shipping options available to suit your destination and budget.

 

 

Wooden-Crate-psd42799 copy

Contact Us

3 Kingley Park, Station Road, Kings Langley, Herts, WD4 8GW

Tel: +44 (0)1923 276007

Fax: +44 (0)1923 267463

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

Here to Help

Product guides

Fuel Specs

Glossary

Selecting a Filter